Click thumbnail image for details
|
|
|
|
|
Amstutz Angled Mirror
|
Angled Capsule Scissors
|
Anterior Femoral Punches
|
NEW! Bechtold Ergonomic Orthopedic Mallet
|
|
|
|
|
|
|
NEW! Bhargava Modular Offset Cup Liner Impactor
|
Blair Acetabular Cup Positioner
|
Bone Clamp with Speed Lock
|
Bone Hooks
|
Bone Hook with Cable/Wire Hole
|
|
|
|
|
|
|
Bradley Periosteal Elevator
|
Browner MIS Bone Clamp
|
Browner Wire Tightener
|
Byrd Arthroscopic Hip Elevators
|
Cannestra Trochanteric Fracture Reduction Clamp
|
|
|
|
|
|
|
Cement Packer & Trimmer
|
Charnley Type Tissue Needle Forceps
|
Chen Diaphyseal Fracture Reduction Clamp
|
Cheng Biopsy Trephine System
|
Clear Vision Debris Shield
|
|
|
|
|
|
|
Curved Canal Rasps
|
Curved Femoral Head Impactor
|
DAA Canal Finder Rasp
|
Delrin Insert Pliers
|
Desai Surgical Funnel
|
|
|
|
|
|
|
DMP Wire Tightener
|
Doroodchi Coated Femoral Neck Mating Guide
|
Duellman Total Hip Trunnion Clamp
|
Expanding Cannulated Corkscrew Femoral Head Remover
|
Extended Cup Positioner
|
|
|
|
|
|
|
Extended Double Action Pliers
|
Femoral Head Removal Pin
|
Femoral Head Removers
|
Femoral Punch
|
Freeman Forceps
|
|
|
|
|
|
|
Gelbke Cobb Elevator
with Suction
|
Huddleston Femoral Head Removers
|
Incavo Wire Passer
|
Kudrna Hip Stem Taper Protectors
|
Jones Mallet
|
|
|
|
|
|
|
Large Bone Clamp with Plate Protection
|
Large T-Handle Fixed Drivers
|
Lighted Yankaur Suction Device
|
Lombardi Bone Hooks
|
Lombardi Cement/Antibiotic Sifter
|
|
|
|
|
|
|
Lombardi Self-Holding X-ray Magnification Marker
|
Long Bonney Tissue Forceps
|
McMaster Medullary Canal Aspirator
|
Modular Head Holder
|
Modular Weights
|
|
|
|
|
|
|
Namba Hip Slide
|
NEW! Offset Canal Finder
|
Offset Cup Liner Inserter
|
NEW! Offset Femoral Rasp
|
O’Reilly Femoral Head Extractor
|
|
|
|
|
|
|
Orthopedic Needle Holder/Scissors
|
NEW! Ortho Mallets
|
Ortho Mallets with Easy Grip Handles
|
Ortho Suction Tube
|
Periosteal Elevator
|
|
|
|
|
|
|
Powers Femoral Sounds
|
Rivero Anti-Rotation Corkscrew Femoral Head Remover Set
|
Rivero Extra Grip
Femoral Head Removers
|
Rockowitz T-Handle Femoral Canal Finder Rasp
|
NEW! Rose Hamstring Tendon Harvester
|
|
|
|
|
|
|
Sanders Femoral Neck
Cutting Blocks
|
Schanz Pin with Zimmer Hall Quick-connect
|
Sarraf Coated
Hip Dislocation Hook
|
Seachris Delrin Cement Scraper
|
Soft Impact Mallets
|
|
|
|
|
|
|
Star Bit Driver Set
|
Stoll Bone Plate Clamp
|
Stoll Retractor/Wire Guide
|
Subtrochanteric Femur Fracture Reduction Clamp
|
Sumko Surgical Finger Guide
|
|
|
|
|
|
|
Surgical Spoon
|
T-Handle Femoral
Canal Finder – Smooth
|
NEW! T-Handle with A0-End
|
Taper Head Impactor
|
Tissue Protector
|
|
|
|
|
|
|
Universal Screw Removal Instrument System
|
Universal Screwdriver Set
|
Verner Corkscrew
Femoral Head Remover
|
Wetzel Acetabular
Fragment Clamp
|
|
|
|
Amstutz Angled Mirror
Used for viewing hard-to-see areas around the acetabulum
|
|
|
|
Designed by Harlan C. Amstutz, MD
|
|
|
|
Product No: 4860
Overall Length: 8" (20,3 cm)
Handle Length: 6.25" (15,9 cm)
Mirror #1: 32 x13 mm
Mirror #2: 19 x16 mm
|
|
|
Angled Capsule Scissors
Angled scissors allow a greater range of capsular access
|
|
|
|
Designed by James B. Stiehl, MD
|
|
|
|
Product No's:
3079 [45°]
Overall Length: 9.5" (24,1 cm)
Scissor Angle: 45°
3082 [20°]
Overall Length: 10" (25,4 cm)
Scissor Angle: 20°
|
|
|
Anterior Femoral Punches
Designed with a delrin pad to help protect the femoral stem trunnion while removing the femoral head during anterior approach total hip revision arthroplasty |
|
|
|
Designed by Brandon Thompson, CST/CFA |
|
|
|
• Three stem angles allow choice of optimal approach
• Angled punches allow for better striking force to help break the taper of the head and stem
•
The delrin pad helps prevent scratching of the femoral stem trunnion
THE DELRIN PAD SHOULD NOT BE USED FOR IMPACTION.
Product No’s:
8626-A [Angled Up]
Overall Length 8.75" (22,2 cm)
Up Angle: 40°
8626-L [Left]
Overall Length: 9" (22,9 cm)
Left Angle: 40°
8626-R [Right]
Overall Length: 9" (22,9 cm)
Right Angle: 40°
|
|
|
Bechtold Ergonomic Orthopedic Mallet
Ergonomically designed for forward and backward strikes, featuring an ergonomic handle with a tamp |
|
|
|
Designed by Dustin Bechtold, MD |
|
|
|
Stainless steel head and shaft with an aluminum handle with a right-handed grip.
Large and small striking heads with smooth surface.
Palmar side of the mallet features a flat surface to slide along a broach or impacting type instrument for back slapping and serves well as an additional striking surface.
Product No: 7822 [2.7 lbs (1,22 kg)]
Weight: 2.7 lbs (1.22 kg)
Overall Length: 10.75" (27,3 cm)
Head Width: 4" (10,2 cm)
Large Head Diameter: 2" (5,1 cm)
Small Head Diameter: 1.5" (3,8 cm)
|
|
|
Bhargava Modular Offset Cup Liner Impactor
Designed to help impact an acetabular cup liner during
minimally invasive direct anterior and MIS posterior approach THR |
|
|
|
Designed by Tarun Bhargava, MD |
|
|
|
Used in conjunction with individual interchangeable heads (sold separately) which fit securely onto the impactor end.
Helps avoid edge loading and improper seating of the liner that can occur with a straight impactor.
Uses the same stainless steel heads as the Innomed CupX Actetabular Cup Extraction System
Product No: 5031
Overall Length: 15.85" (40,2 cm)
Platform End Diameter: 1" (2,54 cm)
|
|
|
Blair Acetabular Cup Positioner
Designed to help adjust the position of an acetabular cup |
|
|
|
Designed by Christopher Blair, DO |
|
|
|
Product No: 4159
Overall Length: 11.5" (29,2 cm)
Shaft Offset: 1" (2,54 cm)
Head Diameter (Inside): 1.18" (3 cm)
Head Diameter (Outside):1.5" (3,8 cm)
|
|
|
Bone Clamp with Speed Lock
Designed to help hold a bone in position for reduction |
|
|
|
|
|
|
|
Product No: 3659
Overall Length: 9.125 (23,2 cm)
|
|
|
Bone Hooks
|
|
|
|
Designed by R.L. Wixson, MD
|
|
|
|
Designed for proximal femoral elevation in total hip replacement or in other surgery with a similar need for bone manipulation. The instrument has a blunt tip and a large handle to accommodate the use of two hands if desired.
Product No's:
5910 [Small]
Curve Diameter: 25 mm
Overall Length: 12.75" (32,4 cm)
Handle Length: 4.75" (12,1 cm)
5915 [Medium]
Curve Diameter: 35 mm
Overall Length: 12.75" (32,4 cm)
Handle Length: 4.75" (12,1 cm)
5920 [Large]
Curve Diameter: 50 mm
Overall Length: 12.75" (32,4 cm)
Handle Length: 4.75" (12,1 cm)
|
|
|
Bone Hook with Cable/Wire Hole
|
|
|
|
Designed by R.L. Wixson, MD & J. McCarthy, MD
|
|
|
|
The instrument has a blunt tip with a 2mm cable/wire hole, and a large handle to accommodate the use of two hands if desired.
Product No: 5920-01
Cable/Wire Hole Diameter: 2 mm
Curve Diameter: 50 mm
Overall Length: 12.75" (32,4 cm)
Handle Length: 4.75" (12,1 cm)
|
|
|
Bradley Periosteal Elevator
|
|
|
|
Designed by Gary W. Bradley, MD |
|
|
|
Product No's:
4719 [1/2"]
Overall Length: 11" (27,9 cm)
Blade Width: .5" (13 mm)
4720 [3/4"]
Overall Length: 11" (27,9 cm)
Blade Width: .75" (19 mm)
|
|
|
Browner MIS Bone Clamp
Designed to help hold a bone or bone plate for fixation, the clamp is inserted anterior to the bone, rotated to wrap around the bone, then screwed into the desired position |
|
|
|
Designed by Bruce D. Browner, MD |
|
|
|
Sized to allow use on a femur, tibia or humerus.
Product No: 1379
Overall Length: 9.25” to 11.5”" (23,5 to 29,2 cm)
Maximum Bone Diameter: ~ 35 mm
|
|
|
Browner Wire Tightener
Wire is passed through the distal arm hole and into the separate drum holes, and can then be tightened and rotated before being cut with a wire cutter
|
|
|
|
Designed by Bruce D. Browner, MD |
|
|
|
Product No: 8251
Overall Length: 6" (15,2 cm)
Width: 3.75" (9,5 cm)
Wire Hole Diameters: .125" (3,2 mm)
|
|
|
Byrd Arthroscopic Hip Elevators
Designed for use in various arthroscopic hip procedures |
|
|
|
Designed by J. W. Thomas Byrd, MD |
|
|
|
he versatile elevators allow freeing up of soft tissue around bone, can assist in removing the fibrous layer off of a cam lesion, and can be used to help elevate the capsule. They are also useful for mobilizing the labrum in preparation for repair or acetabular rim trimming.
Product No’s:
2045 [Extra Long Elevator – Square Tip]
Overall Length: 13.625" (34,6 cm)
Pad Dimensions: 4.8mm x 19mm
2046 [Extra Long Elev. – Angled Joseph Str. Edge]
Overall Length: 13.625" (34,6 cm)
Pad Dimensions: 4.4mm x 12mm
|
|
|
Cannestra Trochanteric Fracture Reduction Clamp
Designed to help reduce comminuted intertrochanteric and subtrochanteric hip fractures, this clamp is offset at its ends to avoid placement into the fracture bed
|
|
|
|
Designed by Vince Cannestra, MD
|
|
|
|
Clamping ends are curved and rotated to allow maximum bony contact upon fracture reduction. Ideal for fractures with a flexed anterior cortical spike. Made for right and left hip fracture configurations.
Product No’s:
3860-L [Left]
Overall Length: 11.25" (28,6 cm)
3860-R [Right]
Overall Length: 11.25" (28,6 cm)
|
|
|
Cement Packer & Trimmer
|
|
|
|
|
|
|
|
Product No: 4995
Overall Length: 9.75" (24,8 cm)
|
|
|
Charnley Type Tissue Needle Forceps
Helpful for wound closure in deep areas with fascia under tension, the forceps can help retrieve a needle in a tight spot
|
|
|
|
Designed by Amal Das Jr., MD
|
|
|
|
Product No: 1165
Overall Length: 6.875" (17,5 cm)
|
|
|
Chen Diaphyseal Fracture Reduction Clamp
Designed to facilitate and maintain reduction of the internal fixation of diaphyseal and meta-diaphyseal fractures of long bones
|
|
|
|
Designed by Franklin Chen, MD |
|
|
|
Works especially well with short oblique ones while providing room to implement the plate with this bone clamp still in place.
• Pivoting pads accommodate metaphyseal fractures
• The quick release enables adjustment without losing reduction
• Helps provide provisional reduction of diaphyseal fractures – humeral shaft fractures, tibial fractures
Product No: 1808
Overall Length: 9.25" (23,5 cm)
Arm Downward Offset: 15 mm
Pad Dimensions: 1" x .375" (25,4 cm x 1 cm)
|
|
|
Cheng Biopsy Trephine System
Using a threaded K-wire facilitates grasping and removal of a core bone sample for biopsy or core decompression
|
|
|
|
Designed by Edward Cheng, MD
|
|
|
|
Designed for use with a standard 1.6mm (.062") threaded K-wire (not included).
-
Allows use of trephine at oblique angles to bone surface by using an anchoring K-wire and cannulated trephine
-
Avoids “skipping” of trephine teeth on bone surface
-
Facilitates optimal approach angle and direction of trephine
-
Variety of core diameters yields bone samples of sufficient size for pathology
-
Adapters allow for use of a power drill
-
Minimally invasive soft tissue sleeve protects surrounding structures and tissue
-
Can also be used for bone graft harvesting
-
Repositioning guide allows easy adjustment of targeting K-wire
Product No: 1425-00 [Complete Set with Case]
Trephine Internal Diameters: 5mm, 6.5mm, 8mm
Set Includes/Available Separately:
1425-01 [Soft Tissue Protector – Small]
1425-02 [Soft Tissue Protector – Medium]
1425-03 [Soft Tissue Protector – Large]
1425-04 [Dilator – 4.75 mm]
1425-05 [Dilator – 6.25 mm]
1425-06 [Dilator – 7.75 mm]
1425-07 [Dilator – 9.25 mm]
1425-08 [Trephine – Small]
Internal Diameter: 5 mm
Overall Length: 7.125" (18,1 cm)
1425-09 [Trephine – Medium]
Internal Diameter: 6.5 mm
Overall Length: 7.125" (18,1 cm)
1425-10 [Trephine – Lage]
Internal Diameter: 8 mm
Overall Length: 7.125" (18,1 cm)
1425-11 [Drive End – Small]
1425-12 [Drive End – Medium]
1425-13 [Drive End – Large]
1425-14 [Driver Retraction Handle]
Includes (2) Handle Retaining Screws (#1425-14-B-COMP)
1425-15 [3-Hole Wire Repositioning Guide]
1425-Case [Case]
Replacement Part:
1425-14-B-COMP [Handle Retaining Screw]
|
|
|
Clear Vision Debris Shield
Provides a degree of restriction from flying debris or liquid during surgery |
|
|
|
Designed by R. Barry Sorrells, MD |
|
|
|
Held between the surgical site and the operating personnel, the shield provides a clear undistorted view, while helping to protect the patient and personnel from possible contamination. The shield is autoclavable and gas sterilizable in a flat position.
Product No: 8031-01
Dimensions:
8" x 10.25" (20,3 cm x 26 cm) (not including handle)
|
|
|
Curved Canal Rasps
Designed for preparation of the femoral canal for insertion of a cemented or cementless hip stem, the multiple diameters serve to prepare the femoral canal after the initial 5 mm is used to find the curvature of the canal |
|
|
|
Design modification by Michael Messieh, MD
of original design by Anthony Unger, MD. |
|
|
|
Product No's:
3004-01-08 [8 mm]
Overall Length: 11" (27,9 cm)
Handle Length: 5" (12,7 cm)
3004-01-10 [10mm]
Overall Length: 11" (27,9 cm)
Handle Length: 5" (12,7 cm)
3004-01-12 [12mm]
Overall Length: 11" (27,9 cm)
Handle Length: 5" (12,7 cm)
|
|
|
Curved Femoral Head Impactor
Allows for in-line femoral head impaction during minimally invasive THR |
|
|
|
Designed by Amiee Zirpel |
|
|
|
The curved offset handle allows the head impactor to be slid under the skin of a small incision, and helps provide hand-held stability and maneuverability within the wound, while the impaction platform is easily accessible outside the wound. The impaction disc is made of delrin, which helps prevent marring and scratching of components.
Product No: 3644
Overall Length: 7.25" (18,4 cm)
|
|
|
DAA Canal Finder Rasp
Designed to help begin preparation of the femoral canal prior to stem broaching — features a large handle with a striking plate end |
|
|
|
|
|
|
|
Product No: C1026
Overall Length: 13.125" (33,4 cm)
Handle Length: 6" (15,2 cm)
Maximum Shaft Diameter: 13 mm
|
|
|
Delrin Insert Pliers
Designed to grasp an implant for adjustment without marring the implant surface |
|
|
|
|
|
|
|
Product No: 2025
Overall Length: 8" (20,3 cm)
Replacement Part:
2025-03 [Replacement Insert]
Includes top and bottom delrin jaws,
two screws and a hex wrench
|
|
|
Desai Surgical Funnel
Helps with control and placement of bone graft or antibiotic beads |
|
|
|
Designed by Sarang Desai, DO |
|
|
|
Made from surgical grade stainless steel (for sterilization purposes).
Product No: 8989
Overall Length: 6.25" (15,9 cm)
Handle Length: 3.25" (8,3 cm)
Funnel Diameter at Top: 3" (7,6 cm)
Funnel Flow-thru Diameter: 11 mm
|
|
|
DMP Wire Tightener
Used to hand tighten a cerclage wire around a bone
|
|
|
|
Designed by DMP
|
|
|
|
Now with four wire holes — two for up to 20 gauge wires, and two for up to 18 gauge wires. T-Handle end is used to hand tighten a wire.
Product No: 8729
Overall Length: 4.5" (11,4 cm)
Handle Width: 2.625" (6,7 cm)
End Diameter: 15 mm
|
|
|
Doroodchi Coated Femoral Neck Mating Guide
Designed for controlled manipulation of femoral head/neck mating in SuperPATH THA approach |
|
|
|
Designed by Hamidreza Doroodchi, MD |
|
|
|
Product No: 3419
Overall Length: 11.75 (29,8 cm)
Blade Width: 1.125" (29 mm)
|
|
|
Duellman Total Hip Trunnion Clamp
Designed for use on a trial modular neck/trunnion at the time of placement on/off the femoral stem to help determine offset and neck length |
|
|
|
Designed by Todd Duellman, MD |
|
|
|
Product No: 1817
Overall Length: 8" (20,3 cm)
|
|
|
Expanding Cannulated Corkscrew Femoral Head Remover
Designed with internal blades which can be expanded from the inside out to better engage a femoral head for successful removal
|
|
|
|
Designed by Tim Seachris
|
|
|
Can be inserted with hand pressure or with tap and turn method. Engagement blades are aligned perpendicular to the large T-handle.
|
Product No: 3710
Overall Length: 10.5" (26,7 cm)
|
|
|
|
|
Extended Cup Positioner
Designed to help reposition an acetabular cup during total hip arthroplasty |
|
|
|
Designed modification by James F. Kayvanfar, MD of an original design by Thomas Eickmann, MD |
|
|
|
Ultra hard titanium nitride coating helps to extend life by increasing surface hardness, prolonging sharpness, and resisting chemicals and corrosion.
Product No: 5475-10
Diameter: 8 mm
Overall Length: 12.75" (32,4 cm)
Handle Length: 4.75" (12,1 cm)
Shaft Length: 8" (20,3 cm)
|
|
|
Extended Double Action Pliers
|
|
|
|
|
|
|
|
Product No’s:
3962 [Needle Nose]
Overall Length: 13" (33 cm)
Jaw Length: 2.625" (6,7 cm)
Jaw Width: 2.5 mm
3961 [Blunt Nose]
Overall Length: 11.75" (29,9 cm)
Jaw Length: 1.25" (3,2 cm)
Jaw Width: 10 mm
|
|
|
Femoral Head Removal Pin
Used to help remove a femoral head during total hip surgery
|
|
|
|
|
|
|
|
Partial threaded pin can be used to help remove a femoral head during total hip surgery. The pin is especially helpful in minimally invasive total hip surgery where access to the femoral head is limited. The pin is attached to a pin driver which clamps onto a Jacob chuck. When the pin is drilled in place, the driver is easily removed from the pin, as the pin is held by a friction ring. The head can be removed by gripping the pin by hand or by using a large pin inserter/extractor. Pin diameter is 5/32”.
Product No: 1310
Overall Length: 9" (22,9 cm)
Pin Diameter: 5/32" (4 mm)
|
|
|
Femoral Head Removers
Used to remove femoral heads during total hip arthroplasty or fracture surgery |
|
|
|
|
|
|
|
Quick-connect version for use with a driver.
Product No's:
3688 [Femoral Head Remover Zimmer Hall Quick-connect]
Overall Length: 8.5" (21,6 cm)
3690 [Femoral Head Remover T-Handle]
Overall Length: 8.75" (22,2 cm)
Quick-connect Driver Available:
8248 [Fixed Driver with Zimmer Hall Quick-connect]
Overall Length: 5.75" (15,6 cm)
Handle Width: 4.625" (11,6 cm)
|
|
|
Femoral Head Disengaging Punch
Designed to help protect the femoral stem trunnion while removing the femoral head |
|
|
|
Designed by Brandon Thompson, CST/CFA |
|
|
|
The delrin pad helps prevent scratching of the femoral stem trunnion. The punch angle allows for better striking force to help break the taper of the head and stem.
THE DELRIN PAD SHOULD NOT BE USED FOR IMPACTION.
Product No: 8626
Overall Length: 9" (22,9 cm)
Shaft Diameter: .5" (12,7 mm)
Punch Platform Offset Angle: 30°
Punch Platform Delrin End: 10 mm x 20 mm
|
|
|
Freeman Forceps
Designed to help with hand pain, fatigue, and hand arthritis
|
|
|
|
Designed by Carl R. Freeman, MD
|
|
|
|
Allows surgeons to utilize a forceps or pickup type instrument using a more mechanically and ergonomically favorable grip. Forceps can be used with a full-hand grip or “palmed.”
Product No: 1174
Overall Length: 6.875" (17,5 cm)
|
|
|
Gelbke Cobb Elevator with Suction
Designed to be used during exposure of the posterior spine, as well as for pelvic and acetabular trauma cases |
|
|
|
Designed by Martin K. Gelbke, MD |
|
|
|
Ultra hard titanium nitride coating helps to extend life by increasing surface hardness, prolonging sharpness, and resisting chemicals and corrosion.
Product No: 3433
Overall Length: 12.75" (32,4 cm)
Cobb End Width: 18 mm (.7")
Shaft plus Head Length: 5.5" (15 cm)
|
|
|
Huddleston Femoral Head Removers
Designed to help lever a femoral head out of the acetabulum in standard and anterior approach total hip replacement |
|
|
|
Designed by H. Dennis Huddleston, MD |
|
|
|
Product No's:
3608 [Sharp]
Overall Length: 10.5" (26,7 cm)
Scoop Length: 3" (7,6 cm)
Scoop Width: 29 mm
3609 [Dull]
Overall Length: 10.5" (26,7 cm)
Scoop Length: 3" (7,6 cm)
Scoop Width: 29 mm
|
|
|
Incavo Wire Passer
Used for passing multiple cerclage wires around bone
|
|
|
|
Designed by Stephen Incavo, MD
|
|
|
|
Designed to pass multiple cerclage wires around a bone during a multiple wire wrap procedure. Accepts a 5/32" (4 mm) diameter wire.
Product No's:
8610-01 [Small]
Overall Length: 7.5" (19,1 cm)
Accepts Wire Up To: 4 mm (5/32")
For Bone Diameter Up To: 1.2" (3 cm)
8610-02 [Large]
Overall Length: 8.675" (21,9 cm)
Accepts Wire Up To: 4 mm (5/32")
For Bone Diameter Up To: 2.4" (6 cm)
|
|
|
Jones Mallet
Unique hand fitting shape provides superior gripping strength
|
|
|
|
Designed by Dickie Jones, MD
|
|
|
|
This striking instrument has a unique hand fitting shape that provides superior gripping strength for accurate light to heavy impaction.
Product No: 7825 [2.4 lbs (1,09 kg)]
Overall Length: 8.25" (21 cm)
Head Width: 3" (7,6 cm)
Head Diameter: 1.5" (3,8 cm
|
|
|
Kudrna Hip Stem Taper Protectors
Used to cover and protect the hip stem taper of a femoral component — especially helpful in cup revision surgery |
|
|
|
Designed by James Kudrna, MD |
|
|
|
Product No's:
1151 [11/13]
1152 [12/14]
1153 [14/16]
|
|
|
Large Bone Clamp with Plate Protection
Designed to help hold a bone/bone plate in position for reduction—the one-side coated jaw helps to protect from marring the bone plate |
|
|
|
|
|
|
|
Left Coated and Right Coated Available
Product No's:
3659-L [Left]
Overall Length: 9.125 (23,2 cm)
3659-R [Right]
Overall Length: 9.125 (23,2 cm)
|
|
|
Large T-Handle Fixed Drivers
Large easy grip soft silicone handled drivers help provide a sturdy non-slip grip
|
|
|
|
|
|
|
|
The two standard Quick-connect models release by pulling the collar backward, while the Reverse Quick-connect model is designed to have the collar be pushed forward for release.
Product No's:
8248 [Zimmer Hall Quick-connect]
Overall Length: 5.75" (15,6 cm)
Handle Width: 4.625" (11,6 cm)
8248-01 [Reverse Quick-connect Zimmer Hall]
Overall Length: 5.75" (15,6 cm)
Handle Width: 4.625" (11,6 cm)
8249 [Hudson Quick-connect]
Overall Length: 5.75" (15,6 cm)
Handle Width: 4.625" (11,6 cm)
|
|
|
Lighted Yankaur Suction Device
Designed to help provide effective suction with the addition of a light source for enhanced visualization |
|
|
|
Designed by Adolph V. Lombardi Jr., MD |
|
|
|
Can be attached to a fiber optic light cable with ACMI (female) connector.
The handle is made of Delrin.
Entire device is steam sterilizable.
Product No's:
8016-L [Lighted Yankaur Suction Device]
Overall Length: 11.75" (29,8 cm)
Handle Length: 3.93" (10 cm)
Handle Width: .86" (2,2 cm)
Suction Tube Diameter: .25" (6,35 mm)
Light Source Cable Adapters
Product No's:
8009-S ACMI to Storz Adapter
8009-W ACMI to Wolf Adapter
|
|
|
Lombardi Bone Hooks
Used to help elevate the femur
|
|
|
|
Designed by Adolph V. Lombardi, Jr., MD
|
|
|
|
3 Sizes Available
Product No’s:
5925 [Small]
Curve Diameter: 25 mm
Overall Length: 10" (25,4 cm)
5930 [Medium]
Curve Diameter: 35 mm
Overall Length: 10" (25,4 cm)
5935 [Large]
Curve Diameter: 55 mm
Overall Length: 10" (25,4 cm)
|
|
|
Lombardi Cement/Antibiotic Sifter
|
|
|
|
Designed by Adolph V. Lombardi Jr., MD |
|
|
|
Product No: 5215
Overall Length: 14" (35,6 cm)
Sifter Diameter: 5" (12,7 cm)
|
|
|
Lombardi Self-holding X-ray Magnification Marker
Helps to remove the variable of X-Ray magnification factor
from the process of Orthopedic templating |
|
|
|
Designed by Adolph V. Lombardi, Jr., MD |
|
|
|
The flexible, adjustable arm can help reduce patient (and technologist) embarrassment or discomfort when it is required to be positioned in a sensitive area such as the inner thigh.
Fully positionable, this orthopedic X-Ray calibration and marking device features a 1" (25.4mm) stainless steel ball which, when properly positioned at bone level on a precise anatomical plane, will be this exact size when viewed from all angles, allowing it be used as a calibration marker in surgical planning software applications, helping to gauge the size of other components on that plane. This helps establish precise anatomical measurement.
Product No: 2672
Base Dimensions: 11" x 5.25" (27,9 x 13,3 cm)
Post Height: 7" (17,8 cm)
Arm Maximum Length: 13" (33 cm)
|
|
|
Long Bonney Tissue Forceps
Extra length—3" (7,6 cm) more than standard—allows for use in deep wound areas |
|
|
|
|
|
|
|
Product No: 5040
Overall Length: 10" (25,4 cm)
|
|
|
McMaster Medullary Canal Aspirator
Designed to aspirate the medullary canal prior to insertion of the solid instrumentation alignment rod to decrease the amount of semi-liquid material present
|
|
|
|
Designed by William McMaster, MD
|
|
|
|
Helps evacuate excess fat and marrow content from the medullary canal of a long bone, helping to reduce the pressure and force created during insertion of a metal rod into the canal, which can possibly cause such materials to be embolized into the circulation system (and eventually into the lungs) through open venous structures.
The guide wire serves a dual purpose: To help break up the medullary bone in the proximal metaphysis to facilitate the passage of the fenestrated rod, and after the procedure to assist in cleaning and clearing the cannulated portion of the rod.
Also can be used on the tibial side if an intramedullary guide system is used. Can also be used during femoral rodding procedures for fractures.
Product No: 8075
Overall Length: 19" (48,3 cm)
Also Available Individually:
8075-01 [Canal Tube]
Overall Length: 18" (45,7 cm)
8075-02 [Guide Wire]
Overall Length: 19" (48,3 cm)
|
|
|
Modified T-Handle Femoral Canal Finder Rasp
Designed to sound the femoral canal prior to stem broaching |
|
|
|
|
|
|
|
MODIFIED DESIGN:
Underside Rasp
Rasp on curve underside and sides, smooth on topside
Product No: 4989
Overall Length: 9" (22,9 cm)
|
|
|
Modular Head Holder
Designed to hold 22mm to 36mm heads for ease of insertion in minimally invasive THR
|
|
|
|
Designed by Byron E. Dunaway, MD &
Wayne Goldstein, MD
|
|
|
|
Head holding ends are plastic coated to help eliminate any damage to the implant. Available in two lengths. Steam and gas sterilizable.
Product No's:
8290-01
Overall Length: 7" (17,8 cm)
8290-02
Overall Length: 9" (22,9 cm)
|
|
|
Modular Weights
Help to free assisting personnel by helping to hold retractors in place
|
|
|
|
|
|
|
|
Designed to hook onto a retractor handle, which helps the retractor stay in place by the weights attached rather than being held. The desired weight can be adjusted by attaching additional weights to the primary weight which has the attaching hook.
Product No’s:
3430-01
Weight: 1.5 lbs. (.68 kg)
3430-02
Weight: 2.0 lbs. (.91 kg)
3430-03
Weight:
2.5 lbs. (1.13 kg) with attaching hook
|
|
|
Namba Hip Slide
Safely glides femoral heads into the acetabulumessential for ceramic heads |
|
|
|
Designed by Robert Namba, MD |
|
|
|
Helps reduce a femoral head trial and implant into the acetabulum during total hip surgery. Manufactured of delrin to help eliminate damage to the implant. Can be steam or gas sterilized and is radiolucent.
Product No’s:
Overall Length: 12" (30,5 cm)
6890 For 2240mm heads
6891 For 4048mm heads
6892 For 5060mm heads
|
|
|
Offset Canal Finder
A smooth, double bent, offset canal finder designed to assist during anterior hip surgery |
|
|
|
|
|
|
|
Product No: 4987
Overall Length: 14" (35,6 cm)
Handle Length: 5.375" (13,6 cm
|
|
|
Offset Cup Liner Inserter
Offset to improve visualization and for mis hip surgery |
|
|
|
|
|
|
|
Product No’s:
5032 [32 mm]
Head Diameter: 32 mm
Overall Length: 16.25" (41,3 cm)
Shaft Diameter: .5" (12.7mm)
5036 [36 mm]
Head Diameter: 36 mm
Overall Length: 16.25" (41,3 cm)
Shaft Diameter: .5" (12.7mm)
5038 [38 mm]
Head Diameter: 38 mm
Overall Length: 16.25"
Shaft Diameter: .5" (12.7mm)
|
|
|
Offset Femoral Rasp
The deep offset design allows the surgeon to line up with canal entry and the tip angled slightly upwards to help prevent femoral protrusion |
|
|
|
Designed by Richard Pelliccio |
|
|
|
Product No: 4988
Overall Length: 13.67" (34,7 cm)
Handle Length: 5.88" (15 cm)
Rasp Offset: 1.5" (3,8 cm)
Download Product Brochure (PDF)
|
|
|
O’Reilly Femoral Head Extractor
Designed to help remove the femoral head—during THA, MIS Direct Anterior THA, and hip fracture surgery/hemiarthroplasty |
|
|
|
Designed by Michael P. O’Reilly, MD. Small version designed modification by Tarum Bhargava, MD |
|
|
|
The perpendicular osteotome blades help provide purchase in osteoporotic bone, while the central osteotome provides a visual estimate of the instrument’s depth of penetration to avoid acetabular injury with use during hemiarthroplasty. The handle helps obtain rotational torque needed to rotate and dislocate the femoral head in direct anterior hip arthroplasty.
Product No's:
3675 [Large]
Overall Length: 9.5" (24,1 cm)
Hammer Platform Diameter: 1.125" (2,9 cm)
Width at End: 1.1"
3674 [Small]
Overall Length: 9.5" (24,1 cm)
Hammer PlatformDiameter: 1.125" (2,9 cm)
Width at End: .75" (1,9 cm)
|
|
|
Ortho Mallets
Designed with a larger diameter and longer handle for a better grip—helps to exert force on osteotomes, chisels, gauges and other instruments |
|
|
|
|
|
|
|
Product No's:
7811 [Standard with Flat Sides]
Overall Length: 7.75" (19,7 cm)
Handle Length: 4.812 (12,2 cm)
Head Diameter: 1.5" (3,8 cm)
Head Weight: 2.25 lb. (1.02 kg)
7812 [Standard]
Overall Length: 7.75" (19,7 cm)
Handle Length: 4.812 (12,2 cm)
Head Diameter: 1.5" (3,8 cm)
Head Weight: 2.5 lb. (1.13 kg)
|
|
|
Ortho Mallets with Easy Grip Handles
Designed to exert force on osteotomes, chisels, gouges and other instruments
|
|
|
|
Cloward-style designed by J. Stiehl, MD
|
|
|
|
These solid stainless steel mallets
each have a comfortable 4-1/2" grip
made of a textured silicone that helps
prevent the surgeon’s gloved hand from
slipping and helps maintain a solid grip.
Product No's:
7810 [Small]
Overall Length: 8" (20,3 cm)
Handle Length: 4.5" (11,4 cm)
Head Weight: 1 lb. (.45 kg)
Head Diameter: 1.3125" (3,3 cm)
7815 [Large]
Overall Length: 8" (20,3 cm)
Handle Length: 4.5" (11,4 cm)
Head Weight: 1.75 lb. (.8 kg)
Head Diameter: 1.5" (3,8 cm)
|
|
|
Ortho Suction Tube
Very effective for suction and minor retracting
|
|
|
|
Designed by T. Eickmann, MD
|
|
|
|
Helps eliminate plugging due to bone, cement fragments, blood clots, etc.
Product No: 5465
Overall Length: 9.25" (23,5 cm)
End Hole Diameter: 1 mm
Side Hole Diameter: 1.5 mm
|
|
|
Periosteal Elevator
Designed for better control
|
|
|
|
|
|
|
|
Designed with sharper sides for ease of elevating and stripping. The handle is designed for better control.
Product No’s:
3450 [Angled Shaft with Straight Blade End]
Overall Length: 7.75" (19,7 cm)
Handle Length: 4.5" (11,4 cm)
Blade Size: 19 x 14 mm
3455 [Straight Shaft with Rounded Blade End]
Overall Length: 7.5" (19,1 cm)
Handle Length: 4.5" (11,4 cm)
Blade Size: 16 x 13 mm
|
|
|
Powers Femoral Sounds
Allows the surgeon to gently identify the canal of a long bone as well as its width (isthmus) prior to inserting a device |
|
|
|
Designed by Mark Powers, MD |
|
|
|
Particularly useful for the anterior approach to the hip. Helps identify intraoperative occult fractures. Properly identifying the medullary canal before broaching helps minimize possible intraoperative fractures.
Product No's:
4189-00 [Set of 5]
Also available individually:
4189-06 [6 mm]
Overall Length: 14.25" (36,2 cm)
Handle Length: 3.5" (8,9 cm)
4189-08 [8 mm]
Overall Length: 14.25" (36,2 cm)
Handle Length: 3.5" (8,9 cm)
4189-10 [10 mm]
Overall Length: 14.25" (36,2 cm)
Handle Length: 3.5" (8,9 cm)
4189-12 [12 mm]
Overall Length: 14.25" (36,2 cm)
Handle Length: 3.5" (8,9 cm)
4189-14 [14 mm]
Overall Length: 14.25" (36,2 cm)
Handle Length: 3.5" (8,9 cm)
|
|
|
Rivero Anti-Rotation Corkscrew Femoral Head Remover
Designed to help prevent rotation while engaging a femoral head for removal
|
|
|
|
Designed by Dennis Rivero, MD |
|
|
|
The sharp-toothed sleeve can be tapped in to help provide purchase of the femoral head, then held to help prevent rotation as the super-threaded corkscrew is turned to engage the head for removal.
Product No's
3705 [Corkscrew & Sleeve Set]
Overall Length: 10" (25,4 cm)
Individual Instruments:
3705-01 [Corkscrew Only]
Overall Length: 10” (25,4c m)
3705-02 [Sleeve Only]
Overall Length: 8” (20,3 cm)
|
|
|
Rivero Extra Grip Femoral Head Removers
Used to remove femoral heads during total hip arthroplasty or fracture surgery |
|
|
|
Modified by Dennis Rivero, MD |
|
|
|
Quick-connect version for use with a driver.
Product No's:
3706 [Zimmer Hall Quick-connect]
Overall Length: 8.5” (21,6cm)
3707 [T-Handle]
Overall Length: 8.75” (22,2cm)
Quick-connect Driver Available:
8248 [Fixed Driver with Zimmer Hall Quick-connect]
Overall Length: 5.75" (15,6 cm)
Handle Width: 4.625" (11,6 cm)
|
|
|
Rockowitz T-Handle Femoral Canal Finder Rasp
Designed to sound the femoral canal prior to stem broaching, especially useful to help start the broach path during the direct anterior approach
|
|
|
|
Designed by Neal L. Rockowitz, MD |
|
|
|
ORIGINAL DESIGN: Topside Rasp
Rasp on curve topside and sides,
smooth on underside
Product No: 4990
Overall Length: 9" (22,9 cm)
|
|
|
Rose Hamstring Tendon Harvester
Designed to easily convert from an open to a closed device without sharp edges to facilitate safe harvesting of hamstring tendon autografts
|
|
|
|
Designed by Donald J. Rose, M.D., FACS, FAAOS |
|
|
|
Product No: 4692
Overall Length: 15" (38,1 cm)
Shaft Length: 9.5" (24,1 cm)
Internal Diameter 5.5 mm
External Diameter: 8 mm
|
|
|
Sanders Femoral Neck Cutting Blocks
Designed to help with the accurate placement of the femoral neck osteotomy in total hip surgery
|
|
|
|
Designed by Richard A. Sanders, MD
|
|
|
|
Used to measure the distance from the proximal end of the lesser trochanter to the level of the femoral neck osteotomy. The desired level of the femoral neck osteotomy is determined by preoperative planning. The exact level of the femoral osteotomy helps with leg length, either maintaining equal leg length or correcting leg length discrepancies.
Product No’s:
4555 [5 x 10 mm]
Overall Length: 6.5" (16,5 cm)
Block: 5 x 10 mm
4560 [10 x 10 mm]
Overall Length: 6.5" (16,5 cm)
Block: 10 x 10 mm
4565 [10 x 15 mm]
Overall Length: 6.5" (16,5 cm)
Block: 10 x 15 mm
4570 [10 x 20 mm]
Overall Length: 6.5" (16,5 cm)
Block: 10 x 20 mm
4575 [10 x 25 mm]
Overall Length: 6.5" (16,5 cm)
Block: 10 x 12 mm
|
|
|
Sarraf Coated Hip Dislocation Hook
Designed to aid in dislocating a femoral stem while helping to prevent damage to the trunnion |
|
|
|
Designed by Khaled M. Sarraf, MD |
|
|
|
Coated hook end helps to prevent from marring component surfaces.
Can also be used as a bone hook, and for femoral elevation.
Product No: 5905
Curve Diameter: 50 mm
Overall Length: 12.5" (31,8 cm)
Handle Length: 4.75" (12,1 cm)
|
|
|
Schanz Pin with Zimmer Hall Quick-connect
Used to help remove a femoral head during total hip surgery |
|
|
|
Designed by Keith Berend, MD |
|
|
|
Product No: 3687
Overall Length: 8.625" (21,9 cm)
Shaft Length: 7.375" (18,7 cm)
Thread Length: 2.5" (6,4 cm)
Diameter: 4.5 mm
|
|
|
Seachris Delrin Cement Scraper
Reusable delrin scraper is designed to help remove cement around a knee or hip prosthesis |
|
|
|
Designed by Timothy Seachris |
|
|
|
Product No: 5218
Overall Length: 5" (12,7 cm)
Thickness: 1/8" (3.1 mm)
|
|
|
Soft Impact Mallets with Easy Grip Handles
Provides shock absorbing force
|
|
|
|
|
|
|
|
Designed to have a shock-absorbing force, providing less bounce or wasted force. The mallet is filled with a shock-absorbing media and has a flat striking surface to keep the mallet centered on an instrument.
The comfortable Easy Grip handle is made of a textured silicone that helps prevent the surgeon’s gloved hand from slipping and helps maintain a solid grip. The bottom can also be used to tap an implant in place.
The mallet with delrin head features a replaceable delrin head.
Product No’s.:
7820 [2 lbs. / .907 kg]
Overall Length: 10.5" (26,7 cm)
Handle Length: 5" (12,7 cm)
Head Width: 3.5" (8,9 cm)
Head Diameter: 1.375" (3,5 cm)
7832 [2 lbs. / .907 kg with Replaceable Delrin Head]
Overall Length: 10.5" (26,7 cm)
Handle Length: 5" (12,7 cm)
Head Width: 3.5" (8,9 cm)
Head Diameter: 1.375" (3,5 cm)
7837 [3 lbs. / 1,36 kg]
Overall Length: 11" (27,9 cm)
Handle Length: 5" (12,7 cm)
Head Width: 3.5" (8,9 cm)
Head Diameter: 1.875" (4,8 cm)
Delrin Head Replacements for 7832:
7832-HEAD01 [.5" Stud] Single
7832-HEAD02 [.5" Stud] 3-Pack
7832-HEAD03 [.875" Stud] Single
7832-HEAD04 [.875" Stud] 3-Pack
|
|
|
Soft Impact Mallet with Weidman Silicone Handle |
|
|
|
Handle designed by Kevin Weidman, MD |
|
|
|
Product No: 7821 [2 lbs. (.907 kg)]
Overall Length: 10.625" (27 cm)
Grip Length: 5.5" (14 cm)
Head Width: 3.5" (8,9 cm)
Head Diameter: 1.375" (3,5 cm)
|
|
|
Star Bit Driver Set |
|
|
|
|
|
|
|
Set consists of four star bits — T10, T15, T20, & T25, a handle which accommodates any of the above bits, and a sterilization case. The drive end (A/O) is designed for easy and quick engagement with the universal instrument handle.
The ergonomic, modular handle has two connection points, allowing for both straight and T-handle orientations.
Product No's:
5194-00 [4 Star Bits w/Handle & Case]
5194-01 [4 Star Bits w/Case only]
Also Available individually:
S0113 [Universal 4" (10,1 cm) Handle]
5194-10 [T10 with A/O End]
5194-15 [T15 with A/O End]
5194-20 [T20 with A/O End]
5194-25 [T25 with A/O End]
9003 [Case]
|
|
|
Stoll Bone Plate Clamp
Designed to help hold a bone or bone plate in position for reduction and fixation—helpful with clavicle and fibula fractures |
|
|
|
Designed by Jordan Stoll, MD |
|
|
|
Product No: 1774
Overall Length: 10" (25,4 cm)
|
|
|
Stoll Retractor/Wire Guide
Retractor/guide designed for aiming guide wire when performing femoral nailing (TFN for an intertrochanteric fracture), or
tibial nailing using the parapatellar approach |
|
|
|
Designed by Jordan Stoll, MD |
|
|
|
Product No: 8012
Overall Length: 12" (30,5 cm)
Blade Width: .71" (1,8 cm)
Prong Length: 6 mm
Guide Hole Diameter: 4,5 mm
|
|
|
Subtrochanteric Femur Fracture Reduction Clamp
Contour design helps clamp a subtrochanteric or femoral shaft fracture treated with current generation femoral IM rodding systems using external aiming arms/targeting devices |
|
|
|
Designed by David Beard, MD |
|
|
|
Product No: 3850
Overall Length: 12.875" (32,7 cm)
Handle Length: 7.5" (19,1 cm)
Jaw Length: 5.25" (13,3 cm)
Jaw Width: .25 (6,3 mm)
|
|
|
Sumko Surgical Finger Guide
Used to help insert a 3.2 mm guide wire, especially during hip fracture surgery, to help prevent puncturing the surgeons’ glove |
|
|
|
Designed by Michael H. Sumko, MD |
|
|
|
The entry point for a trochanteric nail can be located through a smaller incision with this device, with reduced risk of penetrating the surgeon’s glove while finding the starting point for the guide wire.
Product No: 8991
Overall Length: 4" (10,2 cm)
US Patent #503638945
|
|
|
Surgical Spoon
Very useful for the application of methylmethacrylate bone graft |
|
|
|
Designed by David Scott, MD |
|
|
|
Made from surgical grade stainless steel (for sterilization purposes).
Product No: 8209
Overall Length: 5.875" (14,9 cm)
|
|
|
T-Handle Femoral Canal Finder – Smooth
Designed to cut the transverse ligament while helping to protect the suprascapular nerve |
|
|
|
|
|
|
|
Product No: 4990-03
Overall Length: 9.385" (24,4 cm)
|
|
|
T-Handle with A0-End |
|
|
|
|
|
|
|
Product No: 2022-T
Overall Length: 5.9" (15 cm)
Handle Width: 3.15" (8 cm)
|
|
|
Taper Head Impactor
Designed to impact a modular head during minimally invasive THR
|
|
|
|
Designed by Byron E. Dunaway, MD &
Wayne Goldstein, MD
|
|
|
|
The impactor has a protective coating to interface against the implant to help prevent damage while seating the implant. Can be used with 22 to 36 mm heads. Steam and gas sterilizable.
Product No: 7840
Overall Length: 12" (30,5 cm)
|
|
|
Tissue Protector
Helps protect tissue when a straight reamer is being used
|
|
|
|
|
|
|
|
Designed to be used when a straight reamer is being used in a bone canal. Very useful in minimally invasive total hip arthroplasty. Two sizes are available.
Product No’s:
5480-01
Inside Diameter: 19 mm
Overall Length: 6.5" (16,5 cm)
Tube Depth: 3.875" (9,9 cm)
5480-02
Inside Diameter: 24 mm
Overall Length: 6.5" (16,5 cm)
Tube Depth: 3.875" (9,9 cm)
|
|
|
Universal Screw Removal Instrument System
Designed to remove solid and cannulated screws, including partial, broken, stripped, and submerged screws
|
|
|
|
|
|
|
|
Product No’s:
S0010-00 [Complete System with Case]
S0113 [Universal Instrument Handle]
S0128 [1.5 mm Screw Extractor]
S0116 [2.5 mm Screw Extractor]
S0130 [3.5 mm Screw Extractor]
S0117 [1.5 mm Hex Driver]
S0114 [2.5 mm Hex Driver]
S0115 [3.5 mm Hex Driver]
S0132 [4.0 mm Hex Driver]
S0133 [5.0 mm Hex Driver]
S0136 [2.5 mm Cannulated Hex Driver]
S0137 [3.5 mm Cannulated Hex Driver]
S0138 [4.0 mm Cannulated Hex Driver]
S0139 [5.0 mm Cannulated Hex Driver]
S0118 [Large Cruciform Screwdriver]
S0119 [Small Cruciform Screwdriver]
S0141 [Mini Cruciform Screwdriver]
S0120 [Single Slot Screwdriver]
S0121 [2.2 mm Trephine]
S0122 [3.2 mm Trephine]
S0123 [4.2 mm Trephine]
S0124 [4.7 mm Trephine]
S0125 [7.2 mm Trephine]
S0127 [Universal Extractor - Shaft Only]
S0127-01 [Large Extraction Bolt Body]
S0127-03 [Small Extraction Bolt Body]
S0127-04 [Extractor Wrench]
S0129 [Pick]
S0140 [Cannulated Drive Extension]
9017 [Screw Removal Case Only]
Case Dimensions:
21" x 9.5" x 2.25 (53,4 x 24,1 x 5,7 cm) |
|
Used for removal of stripped hex screws, buried screws, and partial screws with broken screw heads. The drive end (A/O) is designed for easy and quick engagement with the universal instrument handle.
Screw Extractors
Unique thread design accommodates removal of stripped screws. The instrument “locks” into the screw head and allows removal once engaged. Designed to be used in a counter-clockwise direction.
Trephines
Designed to fit over submerged screws for extraction with minimal bone loss. Extraction is enhanced by the unique tooth design. Designed to be used in a counter-clockwise direction.
Universal Extractor
Designed to remove screws with heads partially or completely missing. The cone shaped head fully engages the remaining screw and optimizes the force needed for removal. The bolt is disposable and locks into place using a unique thread design. Designed to be used in a counter-clockwise direction.
Hex Drivers
Available in all standard hex sizes. Also offered in a cannulated shaft version for easier removal of buried screws.
Screwdrivers
Standard cruciform screwdrivers in large, small, and mini, and single slot.
Cannulated Drive Extension
Used when a longer instrument shaft is desired.
Pick
Used to remove fragments and bone or tissue from screw head.
Universal Instrument Handle
The single handle allows the surgeon to decide which direction is most efficient and comfortable. The quick-connect release mechanism allows for quick interoperative exchange.
|
|
|
Universal Screwdriver Set
Helps eliminate the opening of multiple sterile packs when a specific size or style of screwdriver is needed
|
|
|
|
|
|
|
|
Helpful during revision total joint surgery where screws have been used, removal of bone plates, fracture fixation screws or bone graft screws. Set consists of: 7 (seven) double ended screwdriver bits — small & large single slot, cross & cruciate, 3.5 mm & 4.5 mm hex, small & large phillips, small, medium, & large star — a handle which accommodates any of the above bits, and a sterilization case.
Product No's: 5195 [Complete Set with Case]
Also available individually:
5195-01 [Handle]
5195-02 [Straight (single slot) Lg & Sm]
Large: 7 x 1.5 mm, Small: 5 x 1 mm
5195-03 [Cross/Cruciate]
Large: 7 mm, Small: 6 mm
5195-04 [Hex]
Large: 4.5 mm, Small: 3.5 mm
5195-05 [Phillips]
Large: 4 mm, Small: 3.5 mm
5195-08 [Small Star: #6 & #8]
5195-06 [Medium Star: #10 & #15]
5195-07 [Large Star: #20 & #25]
|
|
|
Verner Corkscrew Femoral Head Remover
Used to remove the femoral head during total hip arthroplasty or fracture surgery |
|
|
|
Designed by James J. Verner, MD & Andy Lytle |
|
|
|
Designed so the threads engage the head under
power and draws the corkscrew in until the head begins to turn.
The extra long shaft keeps the connected driver out of the operative site for better visualization and improves the lever arm when pivoting the head out of the acetabulum. The grip ring allows the surgeon to pull head out of acetabulum and soft tissue envelope when disengaged from the driver.
Connects with a Zimmer Hall Quick-connect for use with a driver.
Product No: 3698
Overall Length: 12.25" (31,1 cm)
Quick-connect Driver Available:
8248 [Fixed Driver with Zimmer Hall Quick-connect]
Overall Length: 5.75" (15,6 cm)
Handle Width: 4.625" (11,6 cm)
|
|
|
Wetzel Acetabular Fragment Clamp
Designed to help increase the ability to control and manipulate an acetabular fragment during Periacetabular Osteotomy (PAO) surgery for hip dysplasia |
|
|
|
Designed by Robert Wetzel, MD & Todd O. McKinley, MD |
|
|
|
The cannulated center hinge allows a 5 to 6 mm Schantz pin (not included) to be used in conjuction with the clamp — providing a unified pin-and-clamp together that is stronger than each separately and offers enhanced fragment control.
Product No: 3648
Overall Length: 11.5" (29,2 cm)
Jaw Opens to: 1.375" (3,5 cm)
Jaw Length: 2.5" (6,4 cm)
Jaw Width: .5" (12,7 mm)
Hole Diameter for Schantz Pin Up To: .25" (6,3 mm)
|
|
|
© 2023 Innomed, Inc. All rights reserved.
|