Click thumbnail image for details
|
|
|
|
|
|
Anderson Talar Neck Osteotome
|
Angled Capsule Scissors
|
Cannestra Trochanteric Fracture Reduction Clamp
|
Capsule Scissors
|
Cartilage Grasper
|
|
|
|
|
|
|
|
Chung Weitlaner Retractor
|
Curved Cobra Retractors for Total Hip Resurfacing
|
DMP Wire Tightener
with T-Handle
|
Durkan Ratchet Bone Clamp
|
Femoral Elevator for Total Hip Resurfacing
|
|
|
|
|
|
|
|
Femoral Tibial Tensor/Spreader
|
Fracchia Calibrated Tibia/Patella Clamp
|
Lombardi Self-Holding X-ray Magnification Marker
|
Lotke Double Action Graspers
|
Mazzara Rongeur
with Pistol Grip Handle
|
|
|
|
|
|
|
|
McMaster Medullary Canal Aspirator
|
Meniscal Clamp
|
Micro Curettes
|
Mobasser Bayonet Forcep
|
Mongold Capsule Knife
|
|
|
|
|
|
|
|
Mueller-Type Cement
Removal Instruments
|
Offset Cup Liner Inserter
|
Redler ACL Guide Wire Stabilizer
|
Romanelli Deep Gelpi Retractor
|
Rogozinski Offset Ring Curette
|
|
|
|
|
|
|
|
Sanders Femoral Neck Cutting Blocks
|
Shereff Ankle Distractor
|
Shin AccuAngle
|
Soft Impact Mallet Heavy
|
Soft Impact Mallet
With Delrin Head
|
|
|
|
|
|
|
|
Spine Curettes
|
Stablecut® Saw Blades
|
Stanton Forward Army-Navy Retractors
|
Stanton Forward Ragnell Retractors
|
Stanton Forward Senn Retractors
|
|
|
|
|
|
|
|
Tibia Alignment AccuAngle
|
Wubben Guide Rod Pusher
|
|
|
|
|
|
|
Anderson Talar Neck Osteotome
Designed to help improve range of motion and reduce pain caused by anterior boney impingement of the ankle by removing osteophytes from the anterior talar neck and the anterior distal tibia
|
|
|
|
Designed by John Anderson, MD
|
|
|
|

Product No: 5075
Overall Length: 9.875"
Handle Length: 4.5"
Gouge: 17mm Wide, 5mm Deep (Scoop)
|
|
|
Angled Capsule Scissors
Angled scissors allow a greater range of capsular access
|
|
|
|
Designed by James B. Stiehl, MD
|
|
|
|

Product No: 3079
Scissor Angle: 45°
|
|
|
Cannestra Trochanteric Fracture Reduction Clamp
Designed to help reduce comminuted intertrochanteric and subtrochanteric hip fractures, this clamp is offset at its ends to avoid placement into the fracture bed
|
|
|
|
Designed by Vince Cannestra, MD
|
|
|
|

Clamping ends are curved and rotated to allow maximum bony contact upon fracture reduction. Ideal for fractures with a flexed anterior cortical spike. Made for right and left hip fracture configurations.
Product No’s:
Overall Length: 11.25"
3860-L [Left]
3860-R [Right]
|
|
|
Capsule Scissors
|
|
|
|
|
|
|
|

Product No: 3082
Overall Length: 10"
Scissor Angle: 20°
|
|
|
Cartilage Grasper
Helps to grasp and hold cartilage, tendons, soft tissues and loose bodies
|
|
|
|
|
|
|
|

Long 6" shaft allows for use in narrow spaces.
Product No: 1785
Overall Length: 9.25"
|
|
|
Chung Weitlaner Retractor
Features long prongs allowing use of a small retractor in a small, but deep wound
|
|
|
|
Designed by Raymond Chung, MD
|
|
|
Prong lengths of 25mm and 30mm now available
with either sharp or blunt tips.
|

Particularly useful for volar approach to the distal radius in large patients and for mini-open rotator cuff surgery.
Product No’s:
5065 Blunt Tips, 25mm Blade Depth
5066 Sharp Tips, 25mm Blade Depth
5067 Blunt Tips, 30mm Blade Depth
5068 Sharp Tips, 30mm Blade Depth
Overall Length: 4.5"
Opens to Maximum of: 32mm
|
|
|
Curved Cobra Retractors for Total Hip Resurfacing
Left and right retractors can be used with posterior or lateral approach for total hip resurfacing
|
|
|
|
Designed by Henry Boucher, MD
|
|
|
|

Placed over the anterior acetabular wall for supero-anterior translation of the femoral head and neck during acetabular preparation. The two prongs pierce the capsule over the anterior wall, then the curve and “twist” of the retractor allows for gentle retraction on the femoral neck.

Product No’s: 6110-01 [Right] 6110-02 [Left]
|
|
|
DMP Wire Tightener with T-Handle
Used to hand-tighten a cerclage wire around a bone
|
|
|
|
Designed by DMP
|
|
|
|


Can be used on wire up to 18 ga. diameter.
Product No: 8729
Overall Length: 4.5"
Handle Width: 2.625"
End Diameter: 15mm
|
|
|
Durkan Ratchet Bone Clamp
Design of ratcheting mechanism allows for quick tightening and release around the bone
|
|
|
|
Designed by John Durkan, MD
|
|
|
|
Product No: 1867
Overall Length: 8.625"
Jaws Open to: 3.5"
|
|
|
Femoral Elevator for Total Hip Resurfacing
Helps to elevate the femur and provide a trough for bone to collect in during shaping of the femoral head during total hip resurfacing
|
|
|
|
Designed by Henry Boucher, MD
|
|
|
|

Designed for femoral head preparation during total hip resurfacing, the elevator is placed against the anterior femoral neck when the femur is flexed and internally rotated. Helps to elevate the femoral head for milling, and the “trough” provides a channel for the instruments and allows for easy clearance of reamings. Skin, abductor, subcutaneous fat and capsule are protected and retracted with the trough.
Product No: 6030
|
|
|
Femoral Tibial Tensor/Spreader
Used before determining femoral component rotation to help properly tense the medial and lateral ligaments and help assure a stable, balanced flexion gap
|
|
|
|
|
|
|
An important part of surgical technique during total knee arthroplasty is the establishment of a symmetric balanced flexion gap. This can be achieved by tensing the medial and lateral ligaments with laminar spreaders and rotating the femoral component until a rectangular space is formed. The calibrated Tensor/Spreader allows the surgeon to choose a reproducible amount of tension across the medial or lateral flexion space.
In the varus knee, any medial release necessary to balance the knee in extension is performed first. In the valgus knee, the flexion gap can be balanced before the extension gap if the lateral retinaculum (not the lateral collateral ligament) is all that needs releasing to correct the deformity.
|
The spreader can be used before or after tibial preparation and also during revision surgery after a well-aligned tibial platform has been established.
The knee is flexed 90 degrees. Any medial retractor is removed. The medial gap is tensed with a plain or calibrated laminar spreader that is opened until the medial collateral ligament is fully tensed. The calibrated tensor is applied laterally and opened to the desired tension on the indicator. The femoral component is rotated until a rectangular gap is formed based off the tibial cut or an external tibial alignment device (if the tibial resection has not yet been performed).
|
|

Product No: 1995
Overall Length: 7"
Blade Width: 7mm • Opens to 40mm
Patent Pending
|
|
|
Fracchia Calibrated Tibia/Patella Clamp
Designed to be used to remove a tibia wedge, helps in everting the patella, and calibrations help in measuring the thickness of the patella and tibia wedges
|
|
|
|
Designed by Michael J. Fracchia, MD
|
|
|
|


Product No: 3645
Overall Length: 10"
|
|
|
Lombardi Self-holding X-ray Magnification Marker
Helps to remove the variable of X-Ray magnification factor
from the process of Orthopedic templating
|
|
|
|
Designed by Adolph V. Lombardi, Jr., MD
|
|
|

|
The flexible, adjustable arm can help reduce patient (and technologist) embarrassment or discomfort when it is required to be positioned in a sensitive area such as the inner thigh.
Fully positionable, this orthopedic X-Ray calibration and marking device features a 1" (25.4mm) stainless steel ball which, when properly positioned at bone level on a precise anatomical plane, will be this exact size when viewed from all angles, allowing it be used as a calibration marker in surgical planning software applications, helping to gauge the size of other components on that plane. This helps establish precise anatomical measurement.
Product No: 2672
|
|
|
Mazzara Rongeur with Pistol Grip Handle
Pistol Grip handle lessens hand fatigue and slippage, and allows for better visualization
|
|
|
|
Designed by James T. Mazzara, MD
|
|
|
|

Available in three jaw bite sizes.
Product No’s:
Overall Length: 10"
1765-01 • 5 x 14mm
1765-02 • 7 x 16mm
1765-03 • 10 x 16mm
|
|
|
McMaster Medullary Canal Aspirator
Designed to aspirate the medullary canal prior to insertion of the solid instrumentation alignment rod to decrease the amount of semi-liquid material present
|
|
|
|
Designed by William McMaster, MD
|
|
|
|
|

Helps evacuate excess fat and marrow content from the medullary canal of a long bone, helping to reduce the pressure and force created during insertion of a metal rod into the canal, which can possibly cause such materials to be emobilized into the circuclation system (and eventually into the lungs) through open venous structures. The guide wire serves a dual purpose: To help break up the medullary bone in the proximal metaphysis to facilitate the passage of the fenestrated rod, and after the procedure to assist in cleaning and clearing the cannulated portion of the rod. Also can be used on the tibial side if an intramedullary guide system is used. Can also be used during femoral rodding procedures for fractures.
Product No: 8075
|
|
|
Meniscal Clamp
Redesigned clamp is curved for easier use, visualization, and tissue holding
|
|
|
|
|
|
|
|


Product No: 1883
Overall Length: 7"
Teeth Length: .05"
Jaw Length: 1.375"
|
|
|
Micro Curettes
|
|
|
|
|
|
|
|
Four cup sizes, straight or angled shaft.
STRAIGHT
Shaft Length: 4.5"
Product No’s: 4240 Straight Micro Curette • Cup Size 1
4242 Straight Micro Curette • Cup Size 2 4244 Straight Micro Curette • Cup Size 4/0 4246 Straight Micro Curette • Cup Size 6/0
ANGLED 45°
Shaft Length: 4.5"
Product No’s: 4240-01 Angled Micro Curette • Cup Size 1 4242-01 Angled Micro Curette • Cup Size 2 4244-01 Angled Micro Curette • Cup Size 4/0 4246-01 Angled Micro Curette • Cup Size 6/0
|
|
|
Mobasser Bayonet Forcep
|
|
|
|
Designed by Jean Pierre Mobasser, MD
|
|
|
|

Product No: 5082
Overall Length: 10"
Forcep Ends: 5x10mm
|
|
|
Mongold Capsule Knife
|
|
|
|
Designed by Evie Mongold, MD
|
|
|
|

Product No: 4115
Overall Length: 7.75" (19.7 cm)
Blade Diameter: 2" (50.8 mm)
Blade Width: .5" (12 mm)
|
|
|
Mueller-Type Cement Removal Instruments
|
|
|
|
|
|
|
|
Product No's (Top to Bottom):
Narrow Cement Removal Gouge, Short
Product No: S7505
Shaft Length: 150mm
Gouge: 9mm, negative
Narrow Cement Removal Gouge, Long
Product No: S7507
Shaft Length: 240mm
Gouge: 9mm, negative
Narrow Offset Cement Removal Gouge
Product No: S7510
Shaft Length: 240mm
Gouge: 9mm, negative
Acetabular Chisel
Product No: S7515
Shaft Length: 240mm
Chisel: 7.5mm
Offset Chisel
Product No: S7520
Shaft Length: 240mm
Chisel: 9mm
Flared Angle Gouge
Product No: S7525
Shaft Length: 240mm
Gouge: 9mm, positive, angle 15° downward
Wide Gouge
Product No: S7530
Shaft Length: 240mm
Gouge: 11.5mm, negative
“V” Splitter
Product No: S7535
V-Shaped Chisel: 7mm
Cement Splitting Osteotome
Product No: S7590
Shaft Length: 240mm
Cement Removal Osteotome, Short
Product No: S7595
Shaft Length: 150mm
Osteotome: 8mm
Cement Removal Osteotome, Long
Product No: S7597
Shaft Length: 240mm
Osteotome: 8mm
4.4mm Drill
Product No: S7540
4.4mm Drill Guide
Product No: S7545
6.4mm Drill
Product No: S7550
6.4mm Drill Guide
Product No: S7555
Straight Cement Removal Hook
Product No: S7560
Hook Curette: 10mm
Curved Cement Removal Hook
Product No: S7565
Hook Curette: 10mm
Cross Bar
Product No: S7570
7mm T-Handle Conical Tap
Product No: S7575
9mm T-Handle Conical Tap
Product No: S7580
Slotted Mallet
Product No: S7585
Not Shown:
S7587 [Saddle Punch]
S7500-00 [Complete Set with Case]
9075 [Case]
|
|
|
Offset Cup Liner Inserter
Offset to improve visualization and for mis hip surgery
|
|
|
|
|
|
|
|
Product No’s:
5022 [22mm head dia.]
5026 [26mm head dia.]
5028 [28mm head dia.]
5032 [32mm head dia.]
5036 [36mm head dia.]
5038 [38mm head dia.]
Overall Length: 16.25"
Shaft Diameter: .5" (12.7mm)
|
|
|
Redler ACL Guide Wire Stabilizer
Designed to control the guide wire used to direct the reaming or dilating of the tibial tunnel
|
|
|
|
Designed by M.R. Redler, MD
|
|
|
The conical close-ended design helps insure that the guide wire tip remains captured. The tempered nitrate coated steel head helps to minimize the risk of metal shavings being introduced into the joint while the guide wire position is maintained. Designed to work with all ACL instrument sets.

|


Product No: 5210
Overall Length: 9.5"
Handle Length: 4"
Cup: Outside Dia.: 4mm, Inside Dia. 2mm
|
|
|
Redler-Hayes Retractor
|
|
|
|
Designed by M.R. Redler, MD
|
|
|
|
|


Product No: 1645
5" overall length
|
|
|
Rogozinski Offset Ring Curette
Curette is angled to allow access for easier bone preparation for anterior lumbar interbody fusion
|
|
|
|
Designed by Chaim Rogozinski, MD
and Abe Rogozinski, MD
|
|
|
|

Product No: 5020
|
|
|
Romanelli Deep Gelpi Retractor
Offers the versatility and ability to be used on minimally invasive total hip replacements
|
|
|
|
Designed by Ron Romanelli, MD
|
|
|
|
Can be used to hold the hip capsule out of the way for easy visualization, and to allow reaming of the acetabulum without catching the capsule in the reamer. The ends of the retractor have dull tips to help avoid soft tissue damage.
Wider separation occurs at the deep capsule level. Holds the muscle out of the way while retracting the capsule.
Product No: 4270
Overall Length: 7.75"
Depth from Bend: 4.5"
Prong Length: 10mm
|
|
|
Sanders Femoral Neck Cutting Blocks
Designed to help with the accurate placement of the femoral neck osteotomy in total hip surgery
|
|
|
|
Designed by Richard A. Sanders, MD
|
|
|
|

Used to measure the distance from the proximal end of the lesser trochanter to the level of the femoral neck osteotomy. The desired level of the femoral neck osteotomy is determined by preoperative planning. The exact level of the femoral osteotomy helps with leg length, either maintaining equal leg length or correcting leg length discrepancies.
Product No’s: 4555 • 5 x 10 mm
4560 • 10 x 10 mm
4565 • 10 x 15 mm
4570 • 10 x 20 mm
4575 • 10 x 25 mm
|
|
|
Shin AccuAngle
Designed to be attached to the shin with sterilizable straps to help provide a visual reference throughout the knee surgery
|
|
|
|
|
|
|
|
|

(Prototype Show Above)
Product No: 1155
Dimensions: 8"x 3.5"
Set of two velcro® straps included.
|
|
|
Soft Impact Mallet Heavy
Provides shock-absorbing force
|
|
|
|
|
|
|
Easy grip handle
|
Designed to have a shock-absorbing force, providing less bounce or wasted force. The Mallet is filled with a shock-absorbing media and has a flat striking surface to keep the Mallet centered on an instrument. The bottom can also be used to tap an implant in place.
Product No: 7837 [3 lbs. with easy grip handle
Weight: 3 lbs.
Overall Length: 11"
Handle Length: 5"
Head Width: 3.5"
Head Diameter: 1.875"
|
|
|
Soft Impact Mallet with Delrin Head
Provides shock-absorbing force
|
|
|
|
|
|
|
Easy grip handle
|
Designed to have a shock-absorbing force, providing less bounce or wasted force. The Mallet is filled with a shock-absorbing media and has a flat striking surface to keep the Mallet centered on an instrument. The bottom can also be used to tap an implant in place.
Product No: 7832
Weight: 2 lbs
Overall Length: 10.5"
Handle Length: 5"
Head Width: 3.5"
Head Diameter: 1.375"
|
|
|
Spine Curettes
|
|
|
|
|
|
|
|
Oval Cup Curettes with an Up Angle Tip, Offset Bayonet Shaft, and a Two-Handed Handle
Product No’s:
Handle Length: 9.3"
5060-01 • Cup Size 00
5060-02 • Cup Size 0
5060-03 • Cup Size 1
5060-04 • Cup Size 2
|
|
|
Stablecut® Saw Blades
Designed to help in the removal of femoral and tibial components during knee revision surgery, or whenever an extra thin blade is desired
|
|
|
|
|
|
|

Teeth are bent away in an alternating vertical pattern, creating pathways for debris, creating a more aggressive cut.
|
The patented precision oscillating blade design and the hardened stainless steel used to make the blades help give it unequaled accuracy, less vibration and less heat.
At less than 1mm, these thin blades help reduce bone loss when removing an implant.
The patented perpendicular (90 degree) teeth configuration makes for stable, precise cuts and also helps to eject debris more efficiently, creating less friction, to help enhance tissue care surrounding the cut area.
Available with hubs for use with most major power unit manufacturers.
Product No’s:
With hub for use with Stryker® power unit:
2610 [Short Blades: 60mm x 13mm x .89mm]
2615 Long Blades: 90mm x 13mm x .89mm]
Also available with hub ends to fit power units from various other manufacturers please call for product numbers.
Stablecut® is a registered trademark of Synvasive Technology, Inc.
|
|
|
Stanton Forward Retractors
Designed to work as “tissue pushers”, helping to enhance exposure by allowing the surgeon or an assistant to push forward the opposite side of the wound while retracting (or not) the nearer side
|
|
|
|
Designed by John L. Stanton, MD, FACS
|
|
|
|
Helps the assistant to hold the wound open without becoming fatigued and having to reach around to the opposite side of the wound to use another retractor.
|
|
|
Stanton Forward Army-Navy Retractor
|
|
|
|
Designed by John L. Stanton, MD, FACS
|
|
|
|


Product No’s:
4515-01 [Shallow]
4515-02 [Deep]
Overall Length: 9"
Blade Offset from Handle: 2.625"
Blade Width: 18mm
Blade Depth: Shallow 25mm, Deep 43mm
|
|
|
Tibia Alignment AccuAngle
Designed to clamp onto the tibia alignment bar
|
|
|
|
|
|
|
|
|

Product No: 1140
Dimensions: 2" x 1"
|
|
|